    adkinsamandaAug 3, 2025
    How to fix Leuze electronic CML 720i Ex alignment signal too low?
    • T
      Tina NelsonAug 3, 2025
      If the alignment signal is too low on your Leuze electronic Security Sensors, it's likely due to poor alignment between the transmitter and receiver or soiled lens covers. Try these steps: * Adjust the alignment. * Test with a shorter distance between the transmitter and receiver. * Clean the lens cover on both the receiver and the transmitter.
  • P
    Phillip ColemanAug 7, 2025
    Why is the function reserve too low on my Leuze electronic Security Sensors?
    • B
      Bryan CantuAug 7, 2025
      A low function reserve on your Leuze electronic Security Sensors is often caused by poor alignment or dirty lens covers. To resolve this: * Adjust the alignment between the transmitter and receiver. * Test the sensors with a shorter distance between them. * Clean the lens covers on both the receiver and transmitter.
  • A
    Angelica EvansAug 13, 2025
    What to do if Leuze electronic CML 720i Ex Security Sensors show a teach error?
    • L
      Lisa PaceAug 13, 2025
      If your Leuze electronic Security Sensors are displaying a teach error, this could be due to soiling of the lens covers or poor alignment between the transmitter and receiver. The suggested solution is to clean the lens cover on the receiver and the transmitter, and then check the alignment.
  • T
    Timothy RaymondAug 17, 2025
    Why are the outputs not active on Leuze electronic CML 720i Ex?
    • M
      Mark HarrellAug 17, 2025
      If the outputs of your Leuze electronic Security Sensors are not active, or if they change state without a contour change in the measurement field, it may be because configuration data is being read or written. The suggested solution is to end configuration communication.
  • E
    Elizabeth SandersAug 23, 2025
    What to do if Leuze electronic CML 720i Ex Security Sensors supply voltage is not sufficient?
    • J
      Jennifer SimsAug 23, 2025
      If the supply voltage to your Leuze electronic Security Sensors is insufficient, check the voltage supply.
  • W
    Whitney SmithAug 27, 2025
    How to fix corrupt EEPROM data on Leuze electronic CML 720i Ex?
    • R
      Ryan PotterAug 27, 2025
      If the EEPROM data is corrupt on your Leuze electronic Security Sensors, reset the device to factory settings.

Summary

Device Description

General Information and Performance

Basic overview and key technical specifications of the CML 720i Ex.

Connection Technology and Display Elements

Details on device connections, LEDs, and OLED display.

Menu Navigation and Control Panel

Guides on using the control panel, icons, and menu structure.

Functions

Beam Modes and Evaluation Functions

Describes beam scanning modes and methods for evaluating beam states.

Blanking and Interference Suppression

Techniques to manage unwanted beams and noise.

Cascading and Block Evaluation

Connecting multiple units and evaluating specific beam areas.

Switching Outputs and Time Functions

Configuring output behavior and time-related functions.

Mounting and Installation

Mounting Procedures and Alignment

Instructions for physically mounting and aligning the light curtain units.

Fastening Methods and Brackets

Details on using sliding blocks, swivel mounts, and brackets for installation.

Electrical Connection

Shielding and Cable Management

Guidelines for EMC-compliant wiring, shielding, and cable lengths.

Device Connections and Interface Types

Information on connectors, pin assignments, and interface options.

Starting Up the Device - Basic Configuration

Basic Configuration and Alignment

Initial setup including aligning units and teaching environmental conditions.

Extended Configuration Options

Advanced settings for digital I/Os, switching behavior, and display.

Starting Up the Device - IO-Link Interface

IO-Link Device Configuration

Setting up the device for communication via the IO-Link interface.

Starting Up the Device - CANopen Interface

CANopen Basic Configuration

Configuring the device for communication via the CANopen interface.

Example Configurations

Beam-stream Data Configuration

Examples for configuring beam-stream data via IO-Link and CANopen.

Area;Output Mapping Examples

Demonstrates mapping beam areas to output pins and interfaces.

Hole Recognition and Blanking Examples

Examples for hole detection and managing blanking areas.

Smoothing and Cascading Examples

Illustrates smoothing settings and cascading arrangements.

Connecting to a PC - Sensor Studio

System Requirements and Software Installation

Prerequisites and steps for installing Sensor Studio and USB master.

Connecting Hardware and Software

Steps for connecting the USB master, light curtain, and launching software.

Device Manager (DTM) Functions

Overview of the DTM menus for identification, configuration, process, and diagnosis.

Troubleshooting

Diagnosing Failures and LED Indicators

Guidance on interpreting LED status and identifying failure causes.

Error Codes and Their Resolutions

Meaning and resolution of error codes displayed by the device.

Care, maintenance and disposal

Cleaning and Servicing Procedures

Instructions for cleaning, maintenance, and firmware updates.

Service and support

Contact Information and Repair Services

Details for technical support, service hotlines, and repair procedures.

Technical data

General Specifications and Optical Data

Key technical data including operating range, beam spacing, and optical properties.

Timing and Object Detection Limits

Details on response times, cycle times, and minimum object sizes.

Dimensioned Drawings and Accessories

Mechanical dimensions and illustrations of mounting accessories.

Ordering information and accessories

Nomenclature and Part Numbering

Structure for part designations and ordering codes.

Interface and Mounting Accessories

List of accessories for CANopen/IO-Link interfaces and mounting.

PC Connection and Scope of Delivery

Accessories for PC connectivity and items included in the package.

EC Declaration of Conformity

Declaration for Ex Devices

Conformity declaration specific to devices used in potentially explosive environments.

Leuze electronic CML 720i Ex Specifications

General IconGeneral
SeriesCML 720i
Protection classIP 67
Housing materialAluminum
ConnectionM12 connector
ApplicationExplosion protection areas
Operating voltage24 V DC