Electrical connection
Leuze electronic CML 720i Ex 54
Connection cables: see table 17.4
Pin assignment on the long end of the Y-interconnection cable (PWR IN/digital IO)
The pin assignment on the long end of the Y-interconnection cable for synchronization of transmitter and
receiver for devices with fieldbus interface is the same as for IO-Link.
X3 pin assignment (transmitter)
Pin assignment on the transmitter: see table 7.2
Connection cables: see table 17.3
7.5.2 X2 pin assignment – CML 720i Ex with CANopen interface
5-pin, M12 plug (A-coded) for a dev
ice with CANopen interface for connecting to BUS IN/BUS OUT.
1 M12 socket (5-pin, A-coded)
Figure 7.8: X2 connection – CML 720i Ex with CANopen interface
Table 7.4: X2 pin assignment – CML 720i Ex with CANopen interface
Interconnection cables: see table 17.5
7.6 Electrical supply
With regard to the data for the electrical supply, see table 16.6.
3 GND: ground (0 V)
4 C/Q: IO-Link communication
5 IO 2: input/output (configurable)
Ex works: trigger input
Pin X1 - Short end of the Y-interconnection cable
1 2
Pin X2 - CANopen interface
1 SHD: FE functional earth, shield
2n.c.
3 CAN_GND: ground (0 V)
4CAN_H:
5CAN_L: