2024/05
ODSL 8
Technical data
Optical data
Measurement range
1)
1) Diffuse reflection 6% ... 90%, at 20°C, measurement object 20x20mm²
20 200mm
Resolution
2)
2) Minimum and maximum value depend on measurement distance and configuration of the analog output
0.1 0.2mm
Light source Laser
Laser class 2 in acc. with IEC 60825-1:2014 / EN 60825-1:2014+A11:2021
Wavelength 650nm (visible red light)
Max. output power < 1.2mW
Impulse duration 4ms
Light spot Ø 1mm at 200mm
Error limits (relative to measurement distance)
Absolute measurement accuracy
1)
± 2% up to 200mm
Repeatability
3)
3) Same object, identical environmental conditions, measurement object 20x20mm²
± 1% up to 200mm
B/W detection thresh. (6 90% rem.) 1.5%
Temperature drift 0.2%/°C
Time behavior
Measurement time 2 7ms
Response time 20ms
Readiness delay 300ms
Electrical data
Operating voltage U
B
18 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 50mA
Switching output/function
4)
4) The push-pull switching outputs must not be connected in parallel
2 push-pull switching outputs
Pin 2: Q2, PNP light switching, NPN dark switching
Pin 4: Q1, PNP light switching, NPN dark switching
Signal voltage high/low (U
B
-2 V)/ 2V
Analog output Voltage 1 10V, R
L
2kΩ / Current 4 20mA, R
L
< 500Ω
Indicators
Green LED Continuous light Ready
Flashing (no teach) Fault, teach values were not applied
Off No voltage
Yellow LED Continuous light Object within teach-in measurement distance (output Q1
5)
)
5) No display for output Q2
Flashing (no teach) Teach values were not applied
Off Object outside teach-in measurement distance (output Q1
6)
)
Mechanical data
Housing Metal
Optics cover Glass
Weight 70g
Connection type M12 connector, 5-pin, turnable
Environmental data
Ambient temp. (operation/storage) -40°C +50°C/-40°C +70°C
Protective circuit
6)
6) 2=polarity reversal protection, 3=short circuit protection for all outputs
2, 3
VDE protection class
7)
7) Rating voltage 250VAC
II, all-insulated
Degree of protection
8)
8) In end position of the turning connector (turning connector engaged)
IP 67, IP 69K
9)
9) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
Environmentally tested acc. to ECOLAB
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14
Order guide
Designation Part no.
With M12 connector
and voltage output ODSL 8/V66-200-S12 50105761
and current output ODSL 8/C66-200-S12 50108362
Tables
Diagrams
Characteristic curve of switching out-
puts:
Measurement time
depends on the reflectivity
of the measurement object
and on the measurement
mode.
A Hysteresis
B Switching point Q1 (teach
point)
C Switching point Q2 (teach
point)
D Measurement distance
NOTES
Observe intended
use!
This product is not
a safety sensor
and is not intended
as personnel pro-
tection.
The product may
only be put into
operation by com-
petent persons.
Only use the prod-
uct in accordance
with its intended
use.