Parameter Value Description
<group>_<name> value to
assigned
Assign <value> to the parameter <group>_<name>
update <boolean> Set to 1 to actually update all fields (no need to use update
parameter in each group)
return <return
page>
Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or
relative path according the current path. If you omit this
parameter, it will redirect to an empty page.
(note: The return page can be a general HTML
file(.htm, .html) or a LEVELONE server script executable
(.vspx) file. It can not be a CGI command. It can not have
any extra parameters. This parameter must be put at end of
parameter list)
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where <parameter pair> is
<parameter>=<value>\r\n
[<parameter pair>]
Only the parameters that you set and readable will be returned.
Example: Set the IP address of server to 192.168.0.123
Request:
http://myserver/cgi-bin/admin/setparam.cgi?network_ipaddress=192.168.0.123
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: 33\r\n
\r\n
network.ipaddress=192.168.0.123\r\n