To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Sensor is located in electrical box with LINE
connection:
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• Tobeinstalledand/orusedinaccordancewithelectricalcodesandregulations.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,DO NOTinstalltocontrolareceptacle,amotor,oratransformer-operatedappliance
otherthanapplicablespeciedlightingload:Incandescent,LEDorCFL.
• Whenusingina3-wayapplicationuseonesensorandonestandard3-wayswitch.Cannotbeusedwithanothersensor,orina4-wayapplication.
WARNINGS AND CAUTIONS:
• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.
Cleanoutersurfacegentlywithdampclothonly.DO NOT usesoapsorcleaningliquids.
Nouserserviceablecomponents.DO NOT attempttoserviceorrepair.
• UsethisdeviceWITH COPPER OR COPPER CLAD WIRE ONLY.
RESET
RESET
TEST
TEST
1 2
0 3
Push down tabs per
diagram, one at a time and
rotate forward to release
1 2
0 3
1 2
0 3
1 2
0 3
Attach new face by inserting
bottom hinge tabs, then pivot
and snap the color kit to attach
Tools needed to install your Device
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil Cutters Ruler
Changing the color of your device:
Yourdevicemayincludecoloroptions.Tochangecoloroftheface
proceedasfollows:
INSTALLING YOUR DEVICE
NOTE: UsecheckboxeswhenStepsarecompleted.
IMPORTANT:For3-wayapplications,notethatoneofthescrew
terminalsfromtheoldswitchbeingremovedwillusuallybea
differentcolor(Black)orlabeledCommon.Tagthatwirewith
electricaltapeandidentifyasthecommon(LineorLoad)inboththe
sensorwallboxandremotewallbox.
2
4
1
5
3
3-Way
1. LineorLoad (See important
instruction below)
2. Neutral
3. Ground
4. FirstTraveler–notecolor
5. SecondTraveler–notecolor
2
4
3
1
Single-Pole
1. Line(Hot)
2. Neutral
3. Ground
4. Load
Step 2
Identifying your wiring application
(most common):
NOTE:Ifthewiringinthewallboxdoesnotresembleany
ofthesecongurations,consultanelectrician.
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:
GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHotwallboxwiretoterminalscrewmarked"BK".
• Loadwallboxwiretoterminalscrewmarked"RD".
• Terminalscrewmarked"3-way"shouldhaveRedinsulationlabel
afxed.
NOTE: Ifinsulatinglabelisnotafxedtoterminalscrewmarked
"3-way",useelectricaltapetocover.
• ProceedtoStep5.
Use Terminal for 3-Way
Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Hot (Black)
Neutral (White)
Red
Black
Black
White
LOAD
Line
120VAC, 60 Hz
Sensor
Green
Ground
3-Way
(Brass
Screw)
BK
RD
3-Way
Terminal
Screw marked
Red (RD)
2
Terminal
Screw marked
Black (BK)
Brass
Terminal Screw
Marked 3-Way
Terminal Label:
Use Terminal for 3-Way Applications Only.
For Single Pole Applications, Do Not Remove This Label.
4
1
3
Step 4
Single Pole Wiring Application:
Single Pole and 3-Way Wide View Motion Activated Light Control & Dimmer
Cat. No. IPSD6, IPVD6 - INDOOR USE ONLY
Ratings:120VAC,60Hz600WIncandescent&150WDimmableLED&CFL
INSTALLATION INSTRUCTIONS
PK-93918-10-00-2B
FEATURES
• Cat.No.IPSD6andIPVD6haveasensingareaofcoverageof
30ft.x30ft.,andasensingangleof180
O
(see Sensing Area
Coverage figure on page 2).
• Adjustablelight,time-delayandminimumlevelcontrolsare
locatedonthefrontofthedevice(See Adjustment Setting
section on page 2 for details).
• Occupancysensorcanbeconvertedtoavacancysensor
(See adjustment settings on page 2).
• LEDindicatorisusedtoalerttheuserofthestatusofthedevice.
•
AdjustableTimeDelaysettingfor30seconds,5min,15min&30min.
• Adjustablesettingforminimumlightlevel.
LOCATION / MOUNTING
Thedevicerespondstotemperaturechangesandcareshouldbe
takenwhenmountingthedevice.DO NOTmountdirectlyabovea
heatsource,inalocationwherehotorcolddraftswillblowdirectly
onthesensor,orwhereunintendedmotion(e.g.,hallwaytrafc)
willbewithinsensor’seld-of-view.
Preparing and connecting wires:
Thisdevicecanbewiredusingsidewireterminal
screws.Chooseappropriatewirestripping
specicationsaccordingly.
• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if
necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
• For Single Pole Application, go to Step 4A.
• For 3-Way Application with the sensor on the Load side, go to Step 4B.
• For 3-Way Application with the sensor on the Line side, go to Step 4C.
Strip Gage
(measure bare wire
here or use gage on
back of the sensor)
5/8”
(1.6 cm)
Cut
(if necessary)
Side Wire Connection
Sidewireterminalsaccept#14-12
AWGsolid copper wire only.
Step 3
Back Wire
Backwireopeningsuse#14-12
AWGsolid copper wire only.
RD
YL 3-Way
A
C
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
Green
Ground
LOAD/Red
First Traveler
Second Traveler
3-Way Wiring with Single Pole Switch Application:
Whenconnectingthesensorfor3-waycontrol,rstchoosewhich
wallswitchlocationthesensorwillbeinstalledin.Next,identify
whichelectricalboxhasthelineconnection.Ifthelineconnection
isintheboxwherethestandard3-wayswitchislocated,usewiring
diagram4B.Ifthelineconnectionisintheboxwherethesensoris
located,usewiringdiagram4C.
NOTE: Apairofshortpigtailwireswillbeneededforconnectionto
the3-wayswitch.
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
First Traveler
Second Traveler
LOAD/
Red
BK
RD
3-Way
2
2
1
3
5
Common
Terminal
(Black
Screw)
Ground
(Green Screw)
1
4
4
3
5
Common
Terminal
(Black
Screw)
Ground
(Green Screw)
BK
RD
3-Way
2
3
5
1
4
3-Way Switch
2
1
5
4
3
B
Sensor is located in electrical box with LOAD
connection:
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• OnepigtailwiretotheBlackscrewterminalmarked"COM"and
onepigtailwiretotheBrassterminal(same side of switch).
• Connectthefollowing4wiresusinganappropriatelysized
wirenut:
1. Common/Linewire(identified in step 2).
2. SecondTravelerwire(note color from step 2).
3. Twopigtailwiresfromthe3-wayswitch.
• FirstTravelerwallboxwire(note color from step 2)to
Brassscrewterminalontheswitch(opposite side from the
Black screw).
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Common/Loadwallboxwireidentiedwhenremovingold
switch(step 2)toterminalscrewmarked"BK".
• FirstTravelerwallboxwire(note color from step 2)toterminal
screwmarked"3-way".
• SecondTravelerwallboxwire(note color from step 2)to
terminalscrewmarked"RD".ThisTravelerfromtheswitchmust
gototheterminalscrewonthesensormarked"RD".
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Common/Linewallboxwireidentiedwhenremovingoldswitch
(step 2)toterminalscrewmarked"BK".
• FirstTravelerwallboxwire(note color from step 2)toterminal
screwmarked"RD".
• SecondTravelerwallboxwire(note color from step 2)to
terminalscrewmarked"3-way".
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• OnepigtailwiretotheBlackscrewterminalmarked"COM"and
aonepigtailwiretothebrassterminal(samesideofswitch)
• Connectthefollowing4wiresusinganappropriatelysized
wirenut:
1. Common/Loadwire(identified in step 2).
2. FirstTravelerwire(note color from step 2).
3. Twopigtailwiresfromthe3-Wayswitch.
• SecondTravelerwallboxwire(note color from step 2)to
Brassscrewterminalontheswitch(opposite side from the
Black screw).
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1
WARNING:TO AVOID FIRE, SHOCK, OR
DEATH; TURN OFF POWERatcircuitbreakeror
fuseandtestthatpowerisoffbeforewiring!
Question and Answer IconNeed help?

Do you have a question about the Leviton IPSD6 and is the answer not in the manual?

Leviton IPSD6 Specifications

General IconGeneral
BrandLeviton
ModelIPSD6
CategorySecurity Sensors
LanguageEnglish

Summary

Warnings and Cautions

Installing Your Device

Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH

Essential safety warning before starting installation, emphasizing turning off power.

Step 2 Identifying Your Wiring Application

Guide to determine if the setup is single-pole or 3-way.

Step 3 Preparing and Connecting Wires

Instructions on wire preparation and connection methods (side wire or back wire).

Step 4 Single Pole Wiring Application

Detailed wiring steps for a single-pole installation configuration.

Step 4B 3-Way Wiring with Single Pole Switch Application

Wiring steps for a 3-way setup where the sensor is used with a standard switch.

Step 4C 3-Way Wiring with Sensor on Line Side

Wiring steps for a 3-way setup with the sensor located in the electrical box with the line connection.

Step 5 Testing Your Device Prior to Mounting in Wall Box

Adjustment Settings

Troubleshooting

Related product manuals