OMNISTAT2 WIRELESS ZIGBEE ADDENDUM
Cat. No. RC-2000WHZB
Installation Instructions and User’s Guide
INSTALLATION ENGLISH
PK-93332-10-B0-0AAR2253
DESCRIPTION
The Omnistat2 Wireless ZigBee thermostats offer all the features of the standard Omnistat2 thermostats, plus uses ZigBee wireless to communication with the Leviton controller and
other devices on the ZigBee network.
HOME SCREEN
The Home screen now has a signal strength indicator that indicates the signal strength between the Omnistat2 thermostat and the ZigBee Interface Module (ZIM). When the
Omnistat2 is enrolled in the ZigBee network and if it is able to communicate with the ZIM, the bars on the indicator will be illuminated, according to the signal strength. However, if
the Omnistat2 is not enrolled in the ZigBee network or if it is unable to communicate with the ZIM, the bars will appear as four dots.
ZIGBEE SETUP
Enrolling an Omnistat2 to ZigBee Network
Each Omnistat2 Wireless ZigBee thermostat must be individually enrolled. To start the enrollment process on an Omnistat2:
WARNINGS AND CAUTIONS
• Readandunderstandallinstructions.Followallwarningsandinstructionsmarkedontheproduct.
• Donotusethisproductnearwater-e.g.,nearatub,washbasin,kitchensinkorlaundrytub,ina
wet basement, or near a swimming pool.
• Neverpushobjectsofanykindintothisproductthroughopenings,astheymaytouchdangerous
voltages.
• SAVETHESEINSTRUCTIONS.
WARNINGS AND CAUTIONS
• Neverinstallcommunicationswiringorcomponentsduringalightningstorm.
• Neverinstallcommunicationscomponentsinwetlocationsunlessthe
components are designed specifically for use in wet locations.
• Nevertouchuninsulatedwiresorterminalsunlessthewiringhasbeen
disconnected at the network interface.
• Usecautionwheninstallingormodifyingcommunicationswiringor
components.
Omnistat2 enrolled and communicating
Signal
Strength
Indicator
Omnistat2 not enrolled and not communicating
Thursday
5:08pm
45%RH
o
F
Eve
COOL
HEAT
HOLD
Off Cycle Auto
FAN MODE
76
76
59
Thursday
5:08pm
45%RH
o
F
Eve
COOL
HEAT
HOLD
Off Cycle Auto
FAN MODE
76
76
59
ZIGBEE NETWORK
Finding Network...
Back Details Disband
ZIGBEE NETWORK
Enrolled in ZigBee Network
Back Details Disband
FromtheHomescreenontheOmnistat2,presstheScrollWheel.
Tu r n theScrollWheeltohighlight"Setup".
Select"Setup"bypressingtheScrollWheel.
Tu r n theScrollWheeltohighlight"InstallationSettings".
Select"InstallationSettings"bypressingtheScrollWheel.
AcknowledgetheWarningbypressingtheScrollWheel.
Tu r n theScrollWheeltohighlight"ZigBeeNetwork".
Select"ZigBeeNetwork"bypressingtheScrollWheel.
Pressthe"Enroll"buttontobegintheenrollmentprocess.
Enroll the device using the ZigBee Interface Module (ZIM).
(65Z00)
WEB VERSION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leviton OMNISTAT2 and is the answer not in the manual?

Leviton OMNISTAT2 Specifications

General IconGeneral
TypeThermostat
Product TypeZ-Wave Thermostat
CompatibilityZ-Wave
ConnectivityZ-Wave
ProgrammableYes
Z-Wave CertificationYes
Power24V AC
Battery TypeAA
Power Source24VAC
FunctionHeating/Cooling Control