EasyManuals Logo

Lexicon MC-8 User Manual

Lexicon MC-8
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
MC-8 Setup
3-55
INTERNAL NOISE TEST
Opens the INTERNAL NOISE message shown on the previous page,
which indicates that the internal noise test generates loud calibration
noise signals.
When the INTERNAL NOISE message opens:
•Press the arrow button to open the SPEAKER LEVEL ADJUST
menu shown on the previous page. When the SPEAKER LEVEL
ADJUST menu opens, the internal noise test automatically
begins.
•Press the button to skip the internal noise test.
During the internal noise test, the MC-8 sends calibration noise
signals to each speaker in the order shown on the SPEAKER LEVEL
ADJUST menu. The cursor automatically scrolls through output level
parameters, highlighting each parameter as the MC-8 sends the
calibration noise signal to the corresponding speaker. The calibration
noise signal is sent to each speaker for about 4 seconds.
Note:
When the internal noise test begins, the MC-8 automatically sets
volume level to +0dB. Avoid adjusting the master volume level while
the test is in progress, to achieve THX reference levels (75dB).
INTERNAL NOISE TEST LEVELS CALIBRATION MANUAL SPEAKERS SETUP
To manually calibrate output levels during the internal noise test:
1. Set the SPL meter to “C” weighting and “SLOW” response.
2. Place the SPL meter at the primary listening position.
3. Press the or arrow button to highlight the desired output
level parameter. Then, quickly press the button to select this
output level parameter. The horizontal bar graph shown on the
previous page will open in the on-screen display and automatic
scrolling will stop.
Note:
During the internal noise test, it is possible to select an output level
parameter just as the cursor is about to automatically scroll to the
next parameter, causing the MC-8 to send the calibration noise
signal to both speakers. If this occurs, reselect the desired speaker.
4. When the horizontal bar graph opens, press the or button
to select the output level that achieves a 75dB SPL meter reading
from the primary listening position.
5. Press to close the parameter. The internal noise test will
continue and automatic scrolling will resume.
6. Repeat steps 2, 3, 4 and 5 until all desired output levels have
been set.
SPEAKERSSETUP MANUAL LEVELS CALIBRATION
INTERNAL NOISE TEST

Table of Contents

Other manuals for Lexicon MC-8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexicon MC-8 and is the answer not in the manual?

Lexicon MC-8 Specifications

General IconGeneral
BrandLexicon
ModelMC-8
CategoryController
LanguageEnglish

Related product manuals