3-28 Service Manual
7510
Press Stop to return to ENGINE ADJUST.
PRO-CON (ATC sensor setup and adjust)
This procedure is used to adjust the following:
Sensor (C ATC)
Sensor (M ATC)
Sensor (Y ATC)
Sensor (K ATC)
Select PRO-CON and select:
Then Select: Appears on the LCD
ATC Sensor Adjust values
(
Sen Grad SNR-Y Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
Sen Grad SNR-M Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
Sen Grad SNR-C Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
Sen Grad SNR-K Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
SNR Output Ref TC-Y Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
SNR Output Ref TC-M Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
SNR Output Ref TC-C Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
SNR Output Ref TC-K Registration values appear on the LCD. If
required, reset the values and Select to
submit the changes.
ATC Sensor Adjust Cycle Testing... Pass
RegCon (color registration)
This procedure is used to adjust the printhead color registration.
Select RegCon Adjust
and then select:
Appears on the LCD:
Measurement Cycle Reg Measuring Testing...
Control Sensor Check Reg Control Sensor Testing...
Control Sensor Cycle Reg Control Sensor Correction Testing...
Belt Edge Learn Belt Edge Learn Testing...
Select RegCon Adjust
and then select:
Then select: Appears on the LCD:
Control Setup Cycles Skew Fine Setup Skew Fine Setup Testing...
IN/OUT Setup IN/OUT Setup Testing...
Center Setup Center Setup Testing...
Skew Rough Setup Skew Rough Setup Testing...
Cycle Result Value Cycle Result Values appear on the LCD.