Assembly 6: Cables and sensors
Asm-index P/N Units/mach Units/FRU Description Removal procedure
1 40X5429 1 1 ITU paper path thermistor N/A
2 40X5414 2 1 Toner density sensors, left or right (one in
package)
N/A
3 40X7046 1 1 Waste toner bottle sensor N/A
4 40X7636 4 1 Toner cartridge contacts (Pogo pin) N/A
5 40X7835 1 1 UICC to controller board cable (CX310,
CX410, XC2130)
N/A
5 40X7837 1 1 UICC to controller board cable (CX510,
XC2132)
N/A
640X8670 1 1Printhead‑to‑controller board cable N/A
7 40X7618 1 1 Front and right side interlock switch cover
assembly
N/A
8 40X7647 1 1 Cable packet, used for:
• Fuser exit/narrow media to controller
board (8A)
• Fuser motor, thermistor, and duplex
sensor to controller board (8B)
• LVPS to controller board (8C)
• CMY/K motors to controller board (8D)
• Tray 2 to controller board (8E)
• HVPS to controller board (8F)
• Tray present sensor to controller board
(8G)
• AC power to LVPS (8H)
• Speaker cable (NS)
N/A
9 40X7836 1 1 Operator panel USB cable N/A