Figure 10. Blow off valve cleaning
1. Screws 2. Blow off cover
3. Ball valve
1. Screws 2. Blow off cover
3. Ball valve
Note:
VD 160/200 have two ball valves.
7.6 Replace electrical motor
7.6.1 Motor disassembly
To r
eplace the electric motor, do the steps that follow:
1. Remove the fan cover (1).
300766038_002_C3 - 09/2021 - © Leybold
34
Maintenance