24
Upper Punch Penetration
If the tablet needs to be around 1 mm thicker or thinner, you can adjust the Upper Roller Cam.
Tools and Materials Needed
Set of metric Allen keys
Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
Hairnet and/or beard net (food grade products only)
Sterile shoe covers (food grade products only)
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this process.
1. Open the Perspex Casing's front door to gain access to the Upper Roller Cam Pressure Adjuster.
2. Loosen the Upper Roller Cam Pressure Adjuster's bolt with an Allen key.
3. Move the Upper Roller Cam Housing Adjuster to increase or decrease the Upper Punch's
penetration.
3.1 Note: To increase, move clockwise. To decrease, move counterclockwise.
4. Resecure the Upper Roller Cam Pressure Adjuster's bolt with an Allen key.
WARNING: To prevent any potential personal injury, unplug the RTP 9® from
the electrical outlet.