85
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Command reference list
Communication Parameters
y
Baud rate: 9600 bps (UART)
y
Data length: 8 bits
y
Parity : None
y
Stop bit: 1 bit
y
Communication code: ASCII code
y
Use a crossed (reverse) cable.
y
When setting the 17 to 24, a menu does not appear on screen.
y
Note : During USB operations such as Dvix or EMF, all commands except Power(ka) and Key(mc) are
not executed and treated as NG.
COMMAND1 COMMAND2
DATA
(Hexadecimal)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
01. Power k a 00 - 01 14. Treble k r 00 - 64
02. Input Select x b (See p.87) 15. Bass k s 00 - 64
03. Aspect
Ratio
k c (See p.87) 16. Balance k t 00 - 64
04. Screen
Mute
k d 00 - 01
17. Color
Temperature
x u 00 - 64
05. Volume
Mute
k e 00 - 01
18. ISM
Method (
Plasma
)
j p (See p.88)
06. Volume
Control
k f 00 - 64
19. Energy
Saving
j q (See p.88)
07. Contrast k g 00 - 64
20. Auto
Configuration
j u (See p.88)
08. Brightness k h 00 - 64
22. Channel
Add/Del
m b 00 - 01
09. Color k i 00 - 64 23. Key m c (See p.89)
10. Tint k j 00 - 64
24. Backlight
(
LCD
)
m g 00 - 64
11. Sharpness k k 00 - 64
12. OSD Select k l 00 - 01
13. Remote
Control
Lock Mode
k m 00 - 01
COMMAND1 COMMAND2
DATA00
(Hexadecimal)
DATA01
(Hexadecimal)
DATA02
(Hexadecimal)
DATA03
(Hexadecimal)
DATA04
(Hexadecimal)
DATA05
(Hexadecimal)
21. Channel
Tuning
ma
physical
program
high
major
program
low
major low minor high minor low attribute