IP Environment Setup (Cont.)
(Continued from previous page)
IP Conguration
Note: If the server IP address and port number or domain name have already been set in the
EZ-Manager Wizard, the specied data will be reected in the elds displayed.
Note: Setting the Media Type to “IP” automatically sets item 119 DATA CHANNEL in the
Installer Menu to 253. You cannot alter this setting unless you revert Media Type to “RF.” Also,
it is not possible to direct enter “253” in the Installer Menu.
a) The Server Address eld provides the option to specify the domain name of the Pro:Centric
server instead of the server’s IP address. Select/highlight the Server Address eld and press
the Wheel (OK) button on the Installer Remote. Then, use the Up/Down arrow keys to select
either IP Address or Domain Name from the drop-down list of options for dening the server.
b) Depending on your selection in the previous step, either:
Enter the Pro:Centric server IP address in the IP Address eld. The IP address must match
the IPv4 multicast address that is set in the Pro:Centric server.
Enter the Pro:Centric server domain name in the Domain Name eld. Note that in order
for the domain name to be resolved to an IP address, there must be a DNS entry for the
domain name.
For each data entry eld: Use the arrow keys to select the eld and press the Wheel (OK)
button. Then, you can either use the number keys on the Installer Remote to direct enter
data values, or you can use the arrow keys to select the appropriate number(s)/alphanumeric
character(s) from the pop-up virtual keyboard displayed at the bottom of the screen. When
you are done, select Enter from the virtual keyboard, and press the Wheel (OK) button on
the Installer Remote.
c) Enter the Pro:Centric server port number in the Port Number eld. The port number must
match the port number that is set in the Pro:Centric server.
4. Select/highlight the Mode eld and press the Wheel (OK) button on the Installer Remote to
display the drop-down list of Pro:Centric Application Mode options. Then, use the Up/Down
arrow keys to select the appropriate setting—Conguration Only, FLASH, GEM, or HTML.
If the Pro:Centric Application Mode is set to “Conguration Only,” Pro:Centric application data
will not be downloaded.
Note: If the mode has already been set in the Installer Menu (item 098 PRO:CENTRIC) or in
the EZ-Manager Wizard, the specied mode will be reected in this eld. If you change the
mode in this menu, Installer Menu item 098 will now reect the value you selected here.
5. Select/specify the appropriate Update Event setting(s), as required. Based on Update Time
settings, the Wake For Update feature wakes the TV once daily to check for, and if applicable,
download updates from the Pro:Centric server. See Installer Menu item 121 UPDATE TIME HR
description on page 47 for additional information on Wake For Update functionality.
Select/highlight the Update Event eld and press the Wheel (OK) button on the Installer
Remote to toggle the setting as required. When Update Event is enabled, an Update Time
eld is displayed on the screen.