1. Sleep timer operation for cooling cycle
While in cooling mode operation, 30 min. later since the start of the sleep timer, the setting temperature
increase by 1°C. After another 30min. elapse, it increases by 1°C again.
2. Sleep timer operation for heating cycle
While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature
decrease by 1°C. After another 60min. elapse, it decreases by 1°C again.
Setting temp. (˚C)
1.0˚C up
1.0˚C up
Cooling ON temp.
(Setting temp. +0.5˚C)
Cooling OFF temp.
(Setting temp. -0.5˚C)
0.5 1 Sleep time
(
hr
)
Setting temp. (°C)
Heating ON temp.
(Setting temp. +2°C)
Heating OFF temp.
(Setting temp. +4°C)
1 2 Sleep time
(
hr
)
1.0°C down
1.0°C down
When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the
operation of the appliance stops.
When the appliance is on pause, the sleep timer mode cannot be input.
Sleep timer operation

Other manuals for LG AS-W096E1G0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG AS-W096E1G0 and is the answer not in the manual?

LG AS-W096E1G0 Specifications

General IconGeneral
BrandLG
ModelAS-W096E1G0
CategoryAir Conditioner
LanguageEnglish

Related product manuals