4. Trouble Shooting
Cause of
Trouble
Condition Mechanism of Fault Generation
Whirlwind
Blocking of the front part of
outdoor devices
Frequent turning-off of the compressor
: Inflow of high-temperature air generated by
outdoor fans into the air conditioner
Wrong influence to the system in over-load
state
Installation of outdoor devices
in narrow space
Shielding
Blocking of the lateral suction
point on the wall of the outdoor
devices
Foreign substances in the heat
exchanger and obstacles in the
surrounding
Frequent turning-off of the compressor
: Elevation of the pipe temperature due to
reduced wind velocity
Wrong influence to the system in over-load
state
Corrosion
Possible infiltration of moisture
/ highly humid area
Corrosion of heat exchanger Reduced opera-
tion efficiency Transfer of troubles to other
parts
When the front/back has a wall (1 side)
When the front/back/left/right have
walls (2 sides)
When the front/back/left/right
have walls (3 sides)
$IFDLJOHPVUEPPSEFWJDFTGPSTIJFMEJOH
6.7 Troubleshooting Outdoor Error
CH 21 (DC Peak / Comp IPM Fault)

Table of Contents

Other manuals for LG CM24 N14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG CM24 N14 and is the answer not in the manual?

LG CM24 N14 Specifications

General IconGeneral
BrandLG
ModelCM24 N14
CategoryAir Conditioner
LanguageEnglish

Related product manuals