EasyManua.ls Logo

LG F1***ND1 - Troubleshooting; Before Performing Service; QC Test Mode Procedure

LG F1***ND1
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
7. TROUBLESHOOTING
7-1. BEFORE PERFORMING SERVICE
Be careful of electric shock or disconnecting the parts while trouble shooting.
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
7-2. QC TEST MODE.
1
Refer to the page 10~13.
7-3. HOW TO KNOW THE WATER LEVEL FREQUENCY
Refer to the page 10~13.
2
Press Power with above two buttons pressed and then buzzer will sound.
3
Press the Start/Pause button as follows.
[Press the Start/Pause button more 4 times until stop spinning]
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
All lamps turn on
Clockwise spin (right)
Low speed Spin
High speed Spin
Inlet valve for pre-wash operation
Inlet valve for main-wash operation
Hot inlet valve in case of hot water fill
Inlet valve for main-wash operation
Counterclockwise spin (left)
A Heater is in operation for 3 sec.
Draining pump operation
Auto off operation
Motor rpm (About 47)
Motor rpm (About 590~650)
Motor rpm (About 950~1050) : F10**ND(1~9)
Motor rpm (About 1100~1250) : F12**ND(1~9)
Water level frequency (225~265)
Water level frequency (225~265)
Water level frequency (225~265)
Motor rpm (About 47)
Water Temperature
Water level frequency
The digits means water level frequency (10
-1
kHz)
ex) 241 : Water level frequency = 241 X 10
-1
kHz
= 24.1kHz
Pressing number of
[Start/Pause] button
Checking Point
Display Status

Related product manuals