MOTORLOCKED
ERROR
The connector in the LEADWIREASSEMBLY is
not connected to the connector of STATOR
ASSEMBLY.
Reconnect or repair the connector.
The hall sensor is out of order/defective.
Replace the STATORASSEMBLYPage 38
8
9
P
HD
E
OWER
FAILURE
The washer experienced a power failure
Press the start/pause button
10
NFC MODULE
ERROR
The connector in the DISPLAY PCB ASSEMBLY
is not connected to the connector of
NFC PCB ASSEMBLY.
Reconnect or repair the connector.
The NFC HARNESS between the NFC PCB
ASSEMBLY and DISPLAY PCB ASSEMBLY is cut
(open circuited).
Replace the DISPLAY PCB ASSEMBLY.
The NFC PCB ASSEMBLY is out of order/defective.
Replace the NFC PCB ASSEMBLY.
NFC version is not matched.
Replace the NFC PCB ASSEMBLY.
*nC is displayed only in the first screen of the Load
Test Mode.
*nU is displayed only in the first screen of the Load
*The Dry Heater is out of order
*The connector of the Dry Heater is not connected
properlyto the connector in the Main PWB ASSEMBLY
*The Dry fan motor is out of order
Test Mode.
11
12
NFC VERSION
RY
RROR
EATER
ERROR
ERRORSYMPTOMCAUSE
îî