38
Dry Heater Trouble
After power off, is the resistance of Dry Heater out of
range 33 ~ 37Ω?
Is Thermostat closed ?
When checking voltage between connectors(1,2)
on drying, is the voltage AC 220-240V as the figure ?
YES
YES
Replace the Dry Heater.
NO
Replace the Thermostat.
NO
Replace the PWB assembly (main).