MOTOR LOCKED
ERROR
The connector in the LEAD WIRE ASSEMBLY is
not connected to the connector of STATOR
ASSEMBLY.
Page 36
8
9
POWER
FAILURE
The washer experienced a power failure
Press the start/pause button
10
WIFI MODULE
ERROR
The connector in the DISPLAY PCB ASSEMBLY
is not connected to the connector of
WIFI PCB ASSEMBLY.
Reconnect or repair the connector.
The WIFI HARNESS between the WIFI PCB
ASSEMBLY and DISPLAY PCB ASSEMBLY is cut
(open circuited).
Replace the DISPLAY PCB ASSEMBLY.
The WIFI PCB ASSEMBLY is out of order/defective.
Replace the WIFI PCB ASSEMBLY.
WIFI version is not matched.
Replace the WIFI PCB ASSEMBLY.
* nC is displayed only in the first screen of the Load
Test Mode.
* nU is displayed only in the first screen of the Load
Test Mode.
11
WIFI VERSION
ERROR
ERROR SYMPTOM CAUSE