1
Disassembly Top Plate, Control Panel,
Drawer Panel Assembly, Cabinet Cover
Assembly, Lower Cover Assembly
4
Remove pump outlet hose.
5
Remove tub pump bellows.
6
Remove cap(Remaining Hose).
7
Disconnect the wiring.
8
Three screws are unscrewed from the cabinet.
9
Remove the pump to arrow direction.
• Rating : 220/240V 50Hz
• Resistant : 162~176Ω
1
Loosen the nut.
2
Remove washing heater by pulling out.
When assembling the washing heater, insert
the heater to heater clip on the bottom of tub
and check the position of wire color.
PUMP
HEATER
< Heater for Washing>
• Rating : 230V 2000W
• Resistant : 24.5~28.5Ω
CAUTION
Bellows
Pump
Hose
Circulation
Hose
Remaining
Hose