2) Connection of the cable
1. Room Type Indoor Unit
Remove the cover control from the unit by loos-
ening the screw.
Connect the wires to the terminals on the control
board individually.
Secure the cable onto the control board with the
holder (clamper).
Refix the cover control to the original position with
the screw.
Use a recongnized circuit breaker between the
power source and the unit. A disconnection
device to adequately disconnect all supply lines
must be fitted.
2. Art Cool Type Indoor Unit
Connect the cable to the indoor unit by connect-
ing the wires to the terminals on the control
board in dividually according to the outdoor unit
connection.
The earth wire should be longer than the common
wires.
When installing, refer to the circuit diagram on the
Control Box of Indoor Unit.
When installing, refer to the wiring diagram on the
Control Cover Inside Outdoor Unit.
3. Cassette Type Indoor Unit
Open the control box cover and connect the Indoor
power wires.
[Air inlet side view]
Control
box cover
Indoor
power cord
Control box cover