- 58 -
4) Convertible Type Indoor Unit
1) Remove the Air guide - L by loosening 2
screws after removing the Inlet grille from the
Indoor unit.
2) Connect the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively
AIR GUIDE-L
INDOOR UNIT
Control
Panel
1
2
Clamp
GN/YL
The power cord connected to the outdoor unit should be complied
with the following specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
The connecting cable connected to the indoor and outdoor unit should
be complied with the following specifications (Rubber insulation,
type H05RN-F approved by HAR or SAA).
8.5mm
20m
m
GN/YL
7.5mm
20m
m
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
NORMAL
CROSS-SECTIONAL
AREA 3.5mm
2
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its
service agent.
CAUTION
Make sure that the screws of the terminal are free from looseness.