24
Repair the DRAIN HOSE
ASSEMBLY.
Reconnect or repair the
connector
Replace the DRAIN
PUMP ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY.
Is the drain hose twisted or frozen?
Is the connector disconnected or disassembled?
Is the coil of the drain pump too high or low?
(resistance of the coil is 10-20 Ω)
When checking voltage between connectors
(
and ) during drain, is the voltage 220 V AC
as in the figure?
OE ERROR (DRAIN TROUBLE)