7-2-4 LOAD/BUZZER DRIVE & OPEN DOOR DETECTION CIRCUIT
1. Load Drive Condition Check
* When the door of the freezer/refrigerator is left open for 7 minutes or longer, the lamp of the freezer/refrigerator turns off
automatically.
- 27 -
Load Type
COMP
NO.16 NO.12 NO.10 NO.15 NO.14 NO.13 NO.11
1V or below
12V
Defrosting
Lamp
Heater
Fan Motor
Low RPM
Home Bar
Heater
R-Lamp
Fan Motor
HIGH RPM
Measurement Location (IC6)
Condition
ON
OFF

Related product manuals