- 32 -
7-3. RESISTANCE SPECIFICATION OF SENSOR
¥ The resistance of SENSOR has –5% common difference.
¥ Measure the resistance of SENSOR after leaving it over 3 minutes in measuring temperature.
This postponing is necessary because of perceiving speed.
¥ Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE SENSOR RESISTANCE OF FREEZER RESISTANCE OF REFRIGERATOR
SENSOR (DEFROST) SENSOR
- 20 ßC 22.3 K‰ 77 K‰
- 15 ßC 16.9 K‰ 60 K‰
- 10 ßC 13.0 K‰ 47.3 K‰
- 5 ßC 10.1 K‰ 38.4 K‰
0 ßC 7.8 K‰ 30 K‰
+ 5 ßC 6.2 K‰ 24.1 K‰
+ 10 ßC 4.9 K‰ 19.5 K‰
+ 15 ßC 3.9 K‰ 15.9 K‰
+ 20 ßC 3.1 K‰ 13 K‰
+ 25 ßC 2.5 K‰ 11 K‰
+ 30 ßC 2.0 K‰ 8.9 K‰
+ 40 ßC 1.4 K‰ 6.2 K‰
+ 50 ßC 0.8 K‰ 4.3 K‰