- 26 -
Cooling is impossible
Cooling ability is poor
6-3 ANOTHER ELECTRIC COMPONENTS
Compressor doesn't
run.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Cause.
Low voltage.
Shorted.
Lack of capacity.
Poor contacting
and broken.
Coil of motor
Compressor.
Poor contacting.
Coil is shorted.
Shorted.
Check a starting
voltage.
Check if current flows
to starting devices.
Check capacity of OLP.
Check current flowing
in sub-coil of
Compressor.
The items described
above are normal.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
Def. Sensor
FUSE-M
Check current flowing
of the following
components.
Heater plate
Heater cord
Running state of
Compressor is poor.
Fan motor doesn't run.
Much frost are sticked
to the EVAPORATOR.
Replace each
component.
Raise the voltage.
Replace each
component.
Replace the
compressor.
Replace each
component.
Replace each
component.
Replace each
component.