Loading...
- 45 -
CLASSIFICATION
STATE OF TROUBLE
POINT BE CHECKED
STAGECHECKING METHOD CONTENT
REMEDY
COOLING is poor.
REFRIGERATOR
TEMPERATURE is poor.
1.FREEZER
TEMPERATURE is
normal?
2.Cool air of FAN
MOTOR is sufficient?
See "FREEZER
TEMPERATURE is poor".
Certify the amount of cool air and
its speed touching check supplied
into REFRIGERATOR
FAN MOTOR is poor.
Passage of cool air
blocking.
EVA frozen.
Certify the attaching
stateof DOOR.
Replace FAN MOTOR.
Remove impurities.
See "DEFROSTING is
poor".
DEFROSTING is
poor.
NO DEFROSTING. 1. HEATER emit heat?
PRESS TEST KEY on MAIN
PWB three times.
(forced DEFROSTING)
HEATER disconnection.
TEMPERATURE FUSE
disconnection.
Connection is poor.
DEF-SENSOR is poor.
HEATER RELAY is poor.
Replace HEATER.
Replace
TEMPERATURE FUSE.
Certify EVA connection
and wire of MAIN PWB
CONNECTOR
Replace DEF-SENSOR.
Replace RY5 of MAIN
PWB.
2.DRAIN PIPE
blocking?
Certify DRAIN PIPE.
DRAIN PIPE blocking.
Remove ice and
impurities.
Certify HEATER
PLATE resistance.
3.Remain ice at
DEFROSTING?
Certify the attaching of
DEF-SENSOR.
Certify the attaching state(gap) of
FREEZER/REFRIGERATOR
DOOR.
Attaching is poor.
DOOR sticking is poor.
Reassemble
DEF-SENSOR.
Reassemble DOOR.
Replace GASKET.