-161-
Item Function Selection Value
900 MHz ON/OFF
1800 MHz ON/OFF
1900 MHz ON/OFF
900/1800 MHz ON/OFF
Band
Auto ON/OFF
1.3.3. Cell Lock
1.3.4. Network Events
To set the filter of Network Events (RR,SMU,TCM,RMC,PHB,PHB).
1.4. Device
1.4.1. LCD
Item Function Selection Value Description
Set Contrast 0-255 To set the Cntrast of Main LCD.
Set Bias Ratio
0-255
To set the Bias Ratio of Main LCD.
Set Line rate 0-255 To set the Line Rate of Main
LCD.
Set Temperature 0-255 To set the Temperture of Main
LCD.
Set Color To set the value of RGB.
Diplay Demo Pic. To display the picture.
Version
The string to enter Engineering Mode can be changed in the source code.
The larger the value set in the input box ,the brighter the screen is.
1.4.2. GPIO
The GPIO includes List GPIO,GPIO Editor and GPO Editor.
Item Function Selection Value Description
GPIO#5 On/Off To switch GPIO#5 On or Off
GPIO#13
On/Off
To switch GPIO#13 On or Off
GPIO#14
On/Off To switch GPIO#14 On or Off
List
GPO/GPIO
GPIO#15
On/Off To switch GPIO#15 On or Off
GPIO
Editor
View/Edit the state of
the GPIO entered
Enter the GPIO to view and edit the
state:
Current Level:High/Low
Mode:[0~3]
Direction:IN/OUT
GPO
Editor
View/Edit the state of
the GPO entered
Enter the GPO to view and edit the
state:
Current Level:High/Low
Mode:[0~3]
Direction:IN/OUT
List GPO/GPIO is for predefined functional GPIOs. The setting depends on the project
specification.
GPIO Editor and GPO Editor are extensive functionalities,that allow engineers to