Service Manual 21
Installation
1. Connect the wires to the terminals on the control
board individually according to the outdoor unit con-
nection.
Ensure that the color of the wires of outdoor unit
and the terminal No. are the same as those of
indoor unit respectively.
2. Attach the Grille onto the cabinet.
Grasp the lower left and right side of the Grille and
engage four tabs on the top inside edge of the chas-
sis.
Press the Grille toward the chassis until it will be
back into place.
Connect the cable to the indoor unit
CAUTION: Provide a circuit breaker between power source and the unit as shown
below.
WARNING:
Be sure to refer to the wiring diagram label
inside the cover control and carry out the
correct field wiring.
Wrong wiring can cause the unit to misop-
erate to result in a fire hazard.
Check local electrical codes and any speci-
fied wiring instructions or limitations.
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Main power source
Connecting cable