Functions
ƒURoom temperature sensor. (Thermistor)
ƒUMaintains the room temperature in accordance with the Setting Temp.
ƒUIndoor fan is delayed for 5 seconds at the starting.
ƒURestarting is inhibited for approx. 3 minutes.
ƒUHigh, Med, Low
ƒUIntermittent operation of fan at low speed.
ƒUThe setting temperature, indoor fan speed and desired operation mode are automatically set.
ƒUBoth the indoor and outdoor fan stops during defrosting.
ƒUHot start after defrost ends.
ƒUThe indoor fan stops until the evaporator piping temperature will be reached at 28°C.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Soft Dry Operation Mode
Deice (defrost) control (Heating)
Hot-start Control (Heating)
Auto Operation