EasyManua.ls Logo

LG LFC21776ST - Component Testing Information

LG LFC21776ST
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 37 -
11. COMPONENT TESTING INFORMATION
11-1 Defrost Controller Assembly
Function - Controller assembly is consist of 2 kinds of part those are fuse-m and sensor. we can
decide part is defect or not when we check the resistance.
- Fuse-m can cut off the source when defrost heater operate the unusual high temperature.
-Sensor give temperature information to Micom
How to
Measure
(Fuse-M)
Set a ohmmeter to the 2 housing pin.
Measure the 2 pin connected to Fuse-M.
If the ohmmeter indicate below 0.1ohm
fuse-m is a good condition, But infinitely
great ohm Fuse-M is disconnection
How to
Measure
(Sensor)
Set a ohmmeter to The 2housing pin.
Measure the 2 pin connected to Sensor.
If the ohmmeter indicate 11
(at room
temperature) Sensor is not a defect.
When check the ohm at other temperature
Check the sensor manual.
Standard
Sensor (at room temperature)
Test Point
(1) to (2)
Ressult
11
Fuse-M (at all temperature)
Test Point
(1) to (2)
Ressult
0 ~ 0.1
(1) to (2)
(1) to (2)

Other manuals for LG LFC21776ST

Related product manuals