- 46 -
12. TROUBLESHOOTING
Month
1: January O : October
N : November
9: September D : December
~
The information tag provides compressor model, refrigerant, serial number and safety approval
There are two types of controllers used in the linear compressor system.
- The “E”-inverter system is used with the FC75LANE compressor.
- The “A”-inverter system is used with the FC90LANA compressor.
Name Plate
Compressor Label
12-1 INFORMATION OF LINEAR COMPRESSOR
Size : 90mm X 20mm
!
"
1. Compressor Model
2. Refrigerant
3. Serial Number
4. Safety Approval
Ex)
F C 9 0 L A N A
00 00 9 2003 5 13 0012
Series name
DLF/FA/FB
Operating Type
A:A-Inverter
E:E-Inverter
Rated Voltage
& Frequency
-M : 220V 50/60Hz
-N : 115V 50/60Hz
Efficiency version
A:1
st
generation
B:2
nd
generation
Displacement
ex)90=9.0 /stroke
Application Category
-L: LBP with R134a
-H: HBP with R134a
-N: LBP with R600a
Buyer Code
Model Code
Line
Serial No.
Date
Year
*VVVF : Variable Voltage Variable Frequency
**CVCF : Constant Voltage Constant Frequency
FC75LANE
E-Inverter
System
FC90LANA
A-Inverter
System
Refrigerator
Comp On/Off
Comp Drive
Inverter
CVCF
Compressor
Self
Modulation
Controls the
algorithm
according to
various
conditions
Inverter
VVVF
Stroke
Modulation