- 30 -
SymptomCheck Point
1. EIS1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON5
11
th
pin ~ 12
th
pin
Short0
Open OFF
OtherNormal
CON5
11
th
pin ~ 12
th
pin
Resistance [Ω]
-22ºF / -30ºC40k
-13ºF / -25ºC30k
-4ºF / -20ºC23k
-13ºF / -25ºC17k
14ºF / -10ºC13k
23ºF / -5ºC 10k
32ºF / C8k
CON5
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
8-3. Icing Sensor Error (E IS)