EasyManua.ls Logo

LG LFXC24726S - IPM Output Check; Check to Make Sure Compressor Is Receiving Voltage from IPM

LG LFXC24726S
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 87 -
- Measure the voltage between the POWER and COMM pins of the connector as shown below.
Check to make sure compressor is receiving voltage from IPM
- In order to determine whether the compressor is operating normally,
check the output voltage during the refrigeration cycle.
- After initial power-up, when the compressor begins to operate, wait 10
minutes before checking.
- The compressor is operating normally if the voltage is greater than 80V.
IPM Output check

Table of Contents

Other manuals for LG LFXC24726S

Related product manuals