Multi Air Conditioner
SVC MANUAL(General)
MODEL : Multi-Inverter Type
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com

Table of Contents

Other manuals for LG LMU540HV

Question and Answer IconNeed help?

Do you have a question about the LG LMU540HV and is the answer not in the manual?

LG LMU540HV Specifications

General IconGeneral
BrandLG
ModelLMU540HV
CategoryAir Conditioner
LanguageEnglish

Summary

General Information

Safety Precautions

Important safety guidelines and precautions for repair and post-repair checks.

Model Line Up

Details on various indoor and outdoor unit models and their specifications.

Nomenclature

Breakdown of model codes for indoor, outdoor, and branch distributor units.

Functions & Controls

List of Functions & Accessory

Overview of available functions and accessories for indoor and outdoor units.

Air Flow

Explains airflow direction, swing modes, and speed adjustments.

Air Purifying

Information on the PLASMA Air Purifying System and its function.

Installation Functions

Guide to setting External Static Pressure (E.S.P.) for installation.

Reliability

Details on unit reliability features like hot start and self-diagnosis.

Convenience Functions & Controls

Features enhancing user convenience like auto operations and timers.

Special Function & KIT

Advanced functions such as low ambient control and auto elevation grille.

Basic Control

Normal Operation

Basic principles of controlling actuators like compressor, fan, and EEV.

Compressor Control

Fuzzy control logic for compressor operation in cooling and heating modes.

EEV (Electronic Expansion Valve) Control

EEV operation using fuzzy and PI control for superheat management.

Oil Return Control

Operation of components during the oil return cycle.

Defrost Control

Component operation during the defrost cycle.

Protection Control

High pressure, low pressure, discharge temperature, and input current protection.

Test Run

Check Before Test Run

Pre-test run checks for refrigerant leakage, connections, and insulation resistance.

Test Run Flow Chart

Step-by-step flowchart to guide the test run procedure.

Test Running

Procedures for test runs on SPLIT, ART cool, and Ceiling Cassette types.

Trouble Shooting

Self-diagnosis Function

Indoor unit error codes and their corresponding status indicators.

Pump Down

Procedure for gathering refrigerant into the ODU for maintenance.

Evacuation

Steps for evacuating the system using a vacuum pump.

Gas Charging

Procedure for charging refrigerant into the system after evacuation.

Cycle Part

Troubleshooting based on intake/discharge air temperature difference and operating current.

Electronic Parts

Troubleshooting steps for product not operating and specific electronic part failures.

Troubleshooting Indoor Error

Specific error codes for indoor units and their troubleshooting steps.

Troubleshooting Outdoor Error

Specific error codes for outdoor units and their troubleshooting steps.

Service Order

PCB Service Order

Step-by-step instructions for replacing the PCB assembly.