Loading...
Cooling, Soft Dry, Fan, Heating
Sleep Mode
Timer Mode
Hot-start, Defrost
Compressor ON
BUZZER SOUND
Power Input or Reset : One short beep.
When Operation Stop Button is pressed : One long beep.
When Remote Controller Buttons except for Operation Stop are pressed : Two short beep.
- 22 -
Display Function
Self-diagnosis Function
Operation Indicator
Sleep timer Indicator
Timer Indicator
Defrost Indicator or
Hot start Indicator
OUT
DOOR
: Cooling & Heating Model only
: only Cooling Model
CODE NO. DIAGNOSIS Operation Indicator LED Blinks Unit Operation
Once Still Operation
Outdoor pipe thermistor Short/Open Twice Outdoor Unit Off
5 times Stop
Indoor room temperature thermistor or
pipe temperature thermistor Short/Open
Communication failure between indoor and
outdoor
LED blinks as many times as code No. (0.5 second ON/0.5 second OFF) with 3 seconds interval.
While the unit is off, no indication displays.
If more than one code occurs simultaneously, bigger code No. is displayed.