-3-
Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
•
The fan speed is automatically switched from high to low speed.
• The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
• Both the indoor and outdoor fan
stops during deicing.
• The indoor fan stops until the
evaporator piping temperature will be
reached at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
Deice (defrost) control (Heating)
Hot-start Control (Heating)
On/Off : Lights up during the system operation.
: Lights up during Timer operation or
Sleep mode.
Defrost Mode : Lights up during Defrost Mode or Hot
Start operation. (Heat pump model only)
: Lights up during outdoor unit operation.
(Cooling model only)
Plasma Mode : Lights up during plasma-purification
operation.(option)
Auto Restart Mode : Lights up during if Restart Button
is pressed.
Auto Restart Button : In failure of electric power, if the
button is pressed the unit runs as
previous setting operation when
power returns.
Forced Operation Button
: Operation starts, when this button
is pressed and stops when you
press the button again.
Outdoor unit
operation
Timer or
Sleep Mode