7. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
8. Hot-Start Control
ƒU The indoor fan stops until the evaporator piping temperature will be reached at 28¡ . (BY TEMPERATURE)
ƒU The operation diagram is as following.
ƒ¡18ƒ¡
Intake Air temp.                   
Setting temp.+3¡
(Compressor OFF)
Setting temp.
(Compressor ON)
INDOOR FAN Low OFF         Low Low OFF
COMPRESSOR ON OFF ON OFF
ƒU A point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
ƒU B point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
Selecting fan
speed
HOT
START
OFF
Selecting fan
speed
minimum
10sec.
A A
minimum
10sec.
minimum
10sec.
B
¢”
¢”