TROUBLESHOOTING
Issue Cause Corrective Action
There is a burning smell and strange sound 
coming from the unit.
N/A
Immediately turn off the air conditioner and contact your 
installing contractor.
Water leaks from the indoor unit even when 
the humidity level is low.
The power cord is damaged or generating 
excessive heat.
A switch, a circuit breaker (safety, ground) or 
a fuse is not operating properly.
The air conditioner does not work.
The air conditioner will not turn on. Ensure the power cord is plugged into the outlet.
A fuse has blown or the power supply 
is blocked.
Replace the fuse or check if the circuit breaker has tripped.
A power failure has occurred.
Turn off the air conditioner when a power failure occurs. When 
the power is restored, wait 3 minutes, and then turn on the air 
conditioner.
The voltage is too high or too low. Check if the circuit breaker has tripped.
The air conditioner turned off 
automatically at a preset time.
Press the power button.
Battery setting is wrong on the remote 
controller.
• Check to see that the batteries are inserted with the correct 
terminals (+) and (-).
• Replace with new batteries.
The air conditioner does not generate 
cool air.
Air is not circulating properly.
Make sure that no curtains, blinds or furniture are blocking the 
front of the air conditioner.
The air filter is dirty.
Clean the air filter once every 2 weeks. Refer to the “Air Filter - 
Cleaning/Maintenance” section for additional information.
The room temperature is too high.
In the summer it may take additional time to cool indoor air. 
In this case, select jet cool operation to cool the indoor air 
quickly. Refer to “Jet Cool/Jet Heat Operation” for additional 
information.
Cold air is escaping from the room.
Ensure cold air is not escaping through ventilation points in the 
room.
The desired temperature is higher than 
the set temperature.
Set the desired temperature to a level lower than the current 
temperature.
There is a nearby heating source.
Avoid using a heat generator such as an electric oven or gas 
burner while the air conditioner is in operation.
Air circulation operation is selected.
During air circulation operation, air blows from the air 
conditioner without cooling or heating the indoor air. Switch the 
operation mode to cooling operation.
Outside temperature is too high.
Air conditioner cooling capacity may not be sufficient to handle 
hot weather.
Table 7:  Single Zone Mega Wall Mount System Troubleshooting