17) Poor Cooling in Freezer section
CHECKING FLOW RESULT & SERVICE ACTION
1) Turn Off the refrigerator.
2) Remove Grille Fan assembly, and check the
movement of Freezer Fan Motor manually, feel
the rotation condition, then proceed.
6
7
NO.
1) Remove Control Box in refrigerator sensor.
Remove the EPS duct carefully (without disconnect).
Look for damper baffle and check the movement by
entering to TEST MODE 1 (Press once) and TES
MODE 2 (Press once again).
8
Result
Service Action
Replace Freezer Fan
Motor
Tight movement
Free movement
Go to Step 7
Connector must be firmly connected, and wires don’t be
have any damage.
Next action. Go to Step 8.
2) Check for any loose connection.
3) Turn On the refrigerator.
Result
Service Action
TEST
MODE 1
Go to Step 10
Open
Not works
Go to Step 9
Go to Step 10
Close
Go to Step 9
TEST
MODE 2
Not works
TEST MODE 1
Damper OPEN
TEST MODE 2
Damper CLOSE
TEST MODE 1
TEST MODE 2