COOLING ONLY
Rated performance for refrigerant line length of: 7.5m
If 18K Capacity is installed at a distance of 15m, 187.5g of refrigerant
should be added ....................................................(15-7.5)x25g
INDOOR UNIT
H/EX
Liquid SideLiquid Side
COMPRESSOR
ACCUM.
H/EX
Gas SideGas Side
CAPI C1
CAPI A
CAPI B
CAPI C2
OUTDOOR UNIT
GAS LIQUID
Elevation (m)
Length (m)
* Additional
refrigerant
(g/m)
Pipe Size
Rated Rated
Max. Max.
Capacity
18K 5/8" 1/4" 7.5 50 5 30 25
24K 5/8" 1/4" 7.5 50 5 30 30