Use this method to connect several products to a single PC.
You can control several products at a time by connecting them to a single PC.
Connecting the cable
Connect the RS-232C cable as shown in the picture.
* The RS-232C protocol is used for communication between the PC and product. You can
turn the product on/off, select an input source or adjust the OSD menu from your PC.
RS-232C Cable
(not included)
monitor 1 monitor 2 monitor 3
PC
RS-232C Configurations
PC Monitor
RXD TXD
TXD RXD
GND GND
DTR DSR
DSR DTR
RTS _ _ CTS
CTS RTS
D-Sub9 D-Sub9
(Female) (Female)
Communication Parameter
Baud Rate : 9600buadRate (UART)
Data Length : 8bits
Parity Bit : None
Stop Bit : 1bit
Flow Control : None
Communication Code : ASCII code
Use a crossed (reverse)cable
RXD
TXD
GND
DTR
DSR
RTS
CTS
PC
D-Sub9
(Female)
Monitor
D-Sub9
(Female)
monitor 4
TXD
RXD
GND
DTR
DSR
RTS
CTS