7
MASTER-K10S1
F070
~ F077
High speed
counter output
register
• HSCNT instruction : F070 ~ F077
• HSC instruction : use only F070 bit
F080
~ F08F
PLC model • K10S & K10S1 : h0031 • K60S : h0036
• K30S : h0033 • K100S : h0035
F090 20ms clock There relays repeat On/Off with fixed time interval,
and are operated only when the PLC is in RUN
mode.
Example) F094 : 2sec clock
F091 100ms clock
F092 200ms clock
F093 1sec clock
F094 2sec clock
F095 10sec clock
F096 20sec clock
F097 1 minute clock
F100
~ F103
User defined
clock
F100 : Clock 0
~
F103 : Clock 3
These relays repeat On/Off based on a scan time.
(Initial state = Off)
F060
~ F06F
The step No.
where error
occurred
• The step No. where program error occurred in
stored.
• In case of branch instruction error, the destination
step No. is stored.
Relay Name Description
2sec
1sec 1sec
Duty F10x n2n1
n1 n2 n1 n2