EasyManua.ls Logo

LG MS-3446VR - Page 20

LG MS-3446VR
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-10
COMPONENTS TEST PROCEDURE RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Normal:
A: Approx. 85 ~ 100 ohm
B: Approx. 10 ~ 25 ohm
Abnormal: Infinite or several
ohm.
Normal: Approx. 100~150 ohm
Abnormal: Infinite or several
ohm.
NOTE : A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
1
2
3
4
5
6
7
8
9
10
4 sec
6 sec
8 sec
10 sec
12 sec
14 sec
16 sec
18 sec
20 sec
22 sec
18 sec
16 sec
14 sec
12 sec
10 sec
8 sec
6 sec
4 sec
2 sec
0 sec
POWER
LEVEL
Relay 2
A
B
Measure the resistance.
(Ohm-meter scale: R x 1)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 1)