-7-
Fuzzy Operation (C/O Model)
According to the temper ature set by Fuzzy r ule, when the intak e air temp is 0.5 °C or more belo w the setting
temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is turned on.
Compressor ON Temp Setting Temp + 0.5°C
Compressor OFF Temp Setting Temp + 0.5°C
At the beginning of Fuzzy mode oper ation, the setting temper ature is automatically selected according to the
intake air temp at that time.
26°C Intake Air Temp 25°C
24°C Intake Air Temp < 26°C Intake Air Temp + 1°C
22°C Intake Air Temp < 24°C Intake Air Temp + 0.5°C
18°C Intake Air Temp < 22°C Intake Air Temp
Intake Air Temp<18°C 18°C
When the Fuzzy k ey (Temperature Control k ey) is input after the initial setting temper ature is selected, the
Fuzzy key value and the intak e air temper ature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy oper ation, the airflo w speed of the indoor f an is automatically selected according to the
temperature.
Fuzzy Operation (H/P Model)
When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor f an is oper ated for 15 seconds . Then an oper ation mode is selected according to the intak e air
temp at that moment as follows.
24°C Inatake Air Temp Fuzzy Operation for Cooling
21°C Inatake Air Temp<24°C Fuzzy Operation for Dehumidification
Inatake Air Temp<21°C Fuzzy Operation for Heating
If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is tur ned off. When 0.5°C or more above the setting temp, the compressor
is turned on.
Compressor ON Temp Setting Temp +0.5°C
Compressor OFF Temp Setting Temp + 0.5°C
At the beginning of Fuzzy mode oper ation, the setting temper ature is automatically selected according to the
intake air temp at that time.
26°C Intake Air Temp 25°C
24°C Intake Air Temp<26°C Intake Air Temp + 1°C
22°C Intake Air Temp<24°C Intake Air Temp + 0.5°C
18°C Intake Air Temp<22°C Intake Air Temp
Intake Air Temp<18°C 18°C
When the Fuzzy k ey (Temperature Control k ey) is input after the initial setting temper ature is selected, the
Fuzzy key value and the intak e air temper ature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy oper ation, the airflo w speed of the indoor f an is automatically selected according to the tem-
perature.