-8-
2) Fuzzy Operation for Dehumidification
• According to the setting temper ature selected by Fuzzy rule, when the intake air temp is 0.5 °C or more below
the setting temp, the compressor is tur ned off. When 0.5 °C or more abo ve the setting temp , the compressor
is turned on.
Compressor ON Temp ➲ Setting Temp + 0.5°C
Compressor OFF Temp ➲ Setting Temp+0.5°C
• At the beginning of Fuzzy mode oper ation, the setting temper ature is automatically selected according to the
intake air temp at that time.
26°C ≤ Intake Air Temp ➲ 25°C
24°C ≤ Intake Air Temp<26°C ➲ Intake Air Temp+1°C
22°C ≤ Intake Air Temp<24°C ➲ Intake Air Temp+0.5°C
18°C ≤ Intake Air Temp<22°C ➲ Intake Air Temp
Intake Air Temp<18°C ➲ 18°C
• When the Fuzzy k ey (Temperature Control k ey) is input after the initial setting temper ature is selected, the
Fuzzy key value and the intak e air temper ature at that time are compared to select the setting temper ature
automatically according to the Fuzzy rule.
• While in Fuzzy oper ation, the airflo w speed of the indoor f an repeats the lo w airflo w speed or pause as in
dehumidification operation.
3) Fuzzy Operation for Heating
• According to the setting temper ature selected b y Fuzzy r ule, when the intak e air temp is 3 °C or more abo ve
the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on.
Compressor ON Temp ➲ Setting Temp
Compressor OFF Temp ➲ Setting Temp + 3°C
• At the beginning of Fuzzy mode oper ation, the setting temper ature is automatically selected according to the
intake air temp at that time.
20°C≤Intake Air Temp ➲ Intake Air Temp + 0.5°C
Intake Air Temp<20°C ➲ 20°C
• When the Fuzzy k ey (Temperature Control k ey) is input after the initial setting temper ature is selected, the
Fuzzy key value and the intak e air temper ature at that time are compared to select the setting temper ature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the
intake air temperature and the setting temperature.
■ Airflow Speed Selection
• The airflo w speed of the indoor f an is set to high, medium, lo w, or chaos (auto) b y the input of the airflo w
speed selection key on the remote control.
■ On-Timer Operation
• When the set time is reached after the time is input by the remote control, the appliance starts to operate.
• The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
• If the appliance is operating at the time set by the timer, the operation continues.