65
11-2. Cycle Characteristics - Download
Fur/Leather
Pants
Shawls/Neckties
Hush Mode
Winter Warm up
Static Removal
Blanket Warmer
Dress Shirts
Rainy Days
Outdoor/
perfomance
clothing
-
2(M1800)
2(M1800)
2(M1800)
-
2
-
2
2
2
-
-
9
5
5
-
3
-
9
4
6
-
-
-
2
-
-
-
2
-
-
-
3(M1800)
1(M1800)
2(M1400~1600)
-
1(M1800)
-
1(M1800)
1(M1800)
1(M1800)
30(P120/M1600)
20(M1200~1800)
16(P120/M1200~1800)
40(M1400~1800)
10(P120/M1200~1800)
5(P120/M1200~1800)
30(P120/M1200~1800)
100(P120/M1200~1800)
45(P120/M1200~1800)
6(M1200~1800)
-
5
-
9
-
-
-
-
-
3
-
-
-
3
-
-
-
-
-
-
-
3(P180/M1800)
-
2(M1400~1800)
-
-
-
-
-
1(P120/M1800)
-
25(P180/M1200~1800)
-
58(M1400~1800)
-
-
-
-
-
34(P120/M1200~1800)
Moving
hanger
operation
- - -
Operation: 30 seconds after the cycle started
-
Operation: 30 seconds after the cycle started
Component
used
Water supply/
drain pump
Steam heater
Main fan
Motor
Comp
LEV
Steam heater
Water drain
pump
Main fan motor
Steam heater
Main fan motor
-
Main fan motor
M/H motor
Water supply/drain
pump
Comp
LEV
Main fan motor
M/H motor
Steam heater
-
Main fan motor
M/H motor
Water supply/drain
pump
Comp
LEV
Main fan motor
M/H motor
Operation
Heat to 95 ℃
after supplying
water to full
level.
Increase internal
temperature to
maximize the
steam effect.
Operate the steam
heater for the set
duration to inject
steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of wrinkle
removal.
-Sterilization
course turns off all
devices and stands
by to maximize the
sterilization effect.
Operate the steam
heater for the set
duration to inject
steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of wrinkle
removal.
-Sterilization
course turns off all
devices and stands
by to maximize the
sterilization effect.
Operate the steam
heater for the set
duration to inject
steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of wrinkle
removal.
-Sterilization
course turns off all
devices and stands
by to maximize the
sterilization effect.
Operate the main fan
and M/VIH
Operate the main fan
and comp for the set
duration.
Other
Water supply
error occurs
when the full
water level is
not detected
within the
maximum
duration (5
minutes).
When Duct In is
maintained for
10 seconds at
a temperature
above 40 ℃, the
next cycle starts
after 10 minutes.
- When low water
level is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off all
devices and stands
by when the cycle
starts.
- When low water
level is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off all
devices and stands
by when the cycle
starts.
- When low water
level is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off all
devices and stands
by when the cycle
starts.
Operate the main fan
and M/VIH for the set
duration.
Operate the main fan
and comp for the set
duration.
※P:PulleyRPM,M:MotorRPM
※DataViewPulleyRPM=PulleyRPM×3/5
Pre
Steam
Pre
Heat
Steam Cooling SteamStay Drying Stay Cooling Drying