64
11-2. Cycle Characteristics - Sanitary
Normal
Heavy
2(M1800)
2(M1800)
23(M1400~1800)
25(M1400~1800)
6
7
3
3
6
7
3
3
6
7
3
3
3(P120/M1800)
3(P120/M1800)
25(P120/M1200~1800)
25(P120/M1200~1800)
Moving
hanger
operation
- - - - - - - -
Operation: When
the cycle starts
(Sterilization-
Standard)
Stop: When the
course finishes
Component
used
Water supply/
drain pump
Steam heater
Main fan
Motor
Comp
LEV
Steam heater
Water drain
pump
Main fan
motor
STEAM
HEATER
MAIN FAN
MOTOR
MAIN FAN
MOTOR
M/H MOTOR
STEAM
HEATER
MAIN FAN
MOTOR
MAIN FAN
MOTOR
M/H MOTOR
STEAM
HEATER
MAIN FAN
MOTOR
MAIN FAN
MOTOR
M/H MOTOR
MAIN FAN
MOTOR
M/H MOTOR
Water supply/
drain pump
Comp
LEV
Main fan motor
M/H motor
Operation
Heat to 95 ℃
after supplying
water to full
level.
Increase
internal
temperature
to maximize
the steam
effect.
Operate the
steam heater for
the set duration
to inject steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of
wrinkle removal.
-Sterilization
course turns
off all devices
and stands by
to maximize
the sterilization
effect.
Operate the
steam heater for
the set duration
to inject steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of
wrinkle removal.
-Sterilization
course turns
off all devices
and stands by
to maximize
the sterilization
effect.
Operate the
steam heater for
the set duration
to inject steam.
-Styling course
conducts M/H
operation to
maximize the
efficiency of
wrinkle removal.
-Sterilization
course turns
off all devices
and stands by
to maximize
the sterilization
effect.
Operate the main
fan and M/VIH
Operate the main
fan and comp for
the set duration.
Other
Water supply
error occurs
when the full
water level is
not detected
within the
maximum
duration (5
minutes).
When Duct In
is maintained
for 10
seconds at a
temperature
above 40 ℃,
the next cycle
starts after 10
minutes.
- When low
water level
is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off
all devices and
stands by when
the cycle starts.
- When low
water level
is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off
all devices and
stands by when
the cycle starts.
- When low
water level
is detected
during heating,
the next cycle
starts.
- LEV is at 200
when the cycle
starts.
-It turns off
all devices and
stands by when
the cycle starts.
Operate the main
fan and M/VIH for
the set duration.
Operate the main
fan and comp for
the set duration.
※P:PulleyRPM,M:MotorRPM
※DataViewPulleyRPM=PulleyRPM×3/5
Pre
Steam
Pre
Heat
Steam Steam SteamStay Stay Stay Cooling Drying