Code Item Detail Remark
2B Function Sanitary water heating timers
Description
Value #1 Note
Default
Range 5 ~ 95 min (step: 5 min)
Value #2 Note
Default
30 min
Range 0 ~ 600 min (step: 30 min)
180 min
Determine following time duration : operation time of sanitary tank
heating, stop time of sanitary tank heating, and delay time of
sanitary tank heater operating.
This time duration defines how long time sanitary tank heating can
be stopped. It is also regarded as time gap between sanitary tank
heating cycle.
Value #3 Note
Default
Range 20 ~ 95 min (step: 5 min)
20 min
This time duration defines how long time sanitary tank heater
will not be turned on in sanitary water heating operation.
This time duration defines how long time sanitary tank heating can
be continued.
2A
Function Miscellaneous setting
Description Determine electric heater and water heater on and off
Value #1 Note 00: Operate both electric heater and sanitary tank heater
01: Operate only sanitary tank heater
Default 00
Range 00 ~ 01
Value #2 Note Not used
Default -
Range -