- 59 -
  05  
 
  53
Bad communication
between main PCB
assembly(Inverter)
and main PCB as-
sembly(Heater)
• The connector for transmission is dis-
connected
• The connecting wires are miscon-
nected
• The communication line is broken
• main PCB(Heater) is abnormal
• main PCB(Inverter) is abnormal
• Wire connection between control panel
and main PCB 2 should be tight
Code
No.
Description Cause Normal Condition
Is main PCB(Heater)
LED blinking?
Yes 
Yes 
No 
Is main circuit breaker off?
No 
Check the main power 
supply at the unit
terminal block?
Improper connection of power supply cable 
Main power supply problem
Yes 
No 
Yes 
No 
main PCB(Inverter) fault
Replace after checking 
Re-connect transmission cable
No 
Yes 
main PCB(Heater) fault
Replace after checking
Check the insulation of inverter
Check the capacity of main circuit 
breaker and replace if required
If all ok,
Turn on main circuit breaker
Replace main PCB(Inverter) after
checking
Replace TRANS after checking
Check if the 
transmission cable is 
properly connected to 
terminal block of 
main PCB(Heater) and 
main PCB(Inverter)
Control panel 
displays CH05?
Replace main main PCB(Inverter)
Reconnect transmission cable 
between main main PCB(Inverter) 
and control panel